MAINTENANCE

HySpeed HSD130 RHF

Instruction Manual

5-39

4. Remove J3.8 from PCB3 and place a jumper wire between pins 1 and 2 on the cable connector.

a. Make a test cut. If the phase-loss error continues, verify wiring between the connectors J3.8 on PCB3 and

J4.301 on the power supply control board (PCB4) by verifying the continuity between

– J3.8 pin1 to J4.301 pin13

– J3.8 pin2 to J4.301 pin14.

b. If the wiring is OK, replace PCB4. If any wiring is damaged, repair or replace damaged wires.

c. If the phase-loss error goes away while the jumper is on J3.8, make another cut and measure the phase-to-

phase voltage across the fuses F5, F6, and F7. The voltage should be 220 VAC +/–15%. If one of the
3 voltage readings is less than 187 VAC, check the contacts to the contactor, and check for loose connections
between the power cord, contactor, power transformer, and the chopper.

041938

0

4

1935

Power distribution board (PCB3)

Power supply control board (PCB4)