Systems with a fuel-gas console -7, Coolant flow test procedure -24, Coolant flow test procedure – Hypertherm HSD130 HySpeed Plasma User Manual
Page 170

MAINTENANCE
5-24
HySpeed HSD130 RHF
Instruction Manual
1. Turn OFF the power, and remove the right-side panel from the power supply.
Coolant flow test procedure
The control board (PCB4) receives a contact closure signal from the flow switch when the flow rate is 2.3 lpm (0.6 gpm)
or greater. Normal flow is 4.5 lpm (1.2 gpm), but this will vary depending on lead lengths and whether the power is
50 Hz or 60 Hz. PCB4 will allow the system to operate if the coolant flow is 2.3 lpm (0.6 gpm) or greater. If the system
shows a coolant flow error (093) the system will need to be turned OFF and then ON again and the following test
needs to be performed to determine if the problem is coolant flow or the flow switch.
2. Remove the return hose at the top of the coolant tank. Apply gentle pressure to the hose while pulling back on the
collar of the elbow fitting. This will release the coolant hose. No tools required. Put the end of the return hose into a
20 liter (5 gallon) container.
- EDGE Pro Ti Shape Cutting Control Rev.2 (288 pages)
- 80669J Rev.3 (304 pages)
- HD3070 Plasma Arc Cutting System w/ Manual Gas Console (281 pages)
- MAXPRO200 Rev.2 (294 pages)
- MicroEDGE Pro Shape Cutting Control Rev.2 (182 pages)
- HPR260 Auto Gas Preventive Maintenance Program Rev.4 (288 pages)
- Powermax1650 (317 pages)
- Shape Cutting Control (66 pages)
- PHC Sensor (58 pages)
- HTA Rev 6.00 Operators Manual (212 pages)
- HTA Rev 7.00 Install Guide (242 pages)
- THC Control Board Replacement (13 pages)
- THC Plasma Interfacer Upgrade (9 pages)
- THC X-Y Table Product Configuration (20 pages)
- D845GERG2 (128 pages)
- MRT2 (64 pages)
- MRT (98 pages)
- Duramax Hyamp Long Handheld Torches (92 pages)
- Duramax Hyamp Robotic Torch (74 pages)
- HyIntensity Fiber Laser Rev.3 (240 pages)
- PCBS-0124 (70 pages)
- SuperMicro 370SBA 533Mhz (90 pages)
- LR2075 (56 pages)
- Phoenix 8.0 (585 pages)
- LH2125 (60 pages)
- HD3070 w/ Automatic Gas (35 pages)
- HD3070 w/Manual Gas (43 pages)
- HD4070 Rev.8 (278 pages)
- HD4070 Product Configuration (88 pages)
- HPR800XD Manual Gas Preventive Maintenance Program Rev.1 (32 pages)
- HPR800XD Manual Gas Preventive Maintenance Program Rev.1 (33 pages)
- HPR800XD Manual Gas Rev.2 (368 pages)
- HPRXD Short Torch with Integrated Lead Rev.1 (30 pages)
- HT4001 (59 pages)
- DuraChill 5 HP Air-Cooled Chiller For Hypertherm (29 pages)
- HT4001 Air Injected Water Muffler System (40 pages)
- H601 Power Supplies (62 pages)
- MAX200 Remote Switch (9 pages)
- HT4100 Plasma Arc Cutting System Operating (50 pages)
- HT4001 Plasma Arc Cutting System (259 pages)
- HySpeed HT2000 Plasma Arc Cutting System Rev.7 (53 pages)
- HySpeed HT2000 Plasma Arc Cutting System Rev.27 (289 pages)
- MAX200 Water Muffler (39 pages)
- HT2000LHF Product Configuration (23 pages)