Error codes -9, Gas leak test procedure -26, Gas leak test procedure (standard system) – Hypertherm HSD130 HySpeed Plasma User Manual
Page 172
MAINTENANCE
5-26
HySpeed HSD130 RHF
Instruction Manual
Gas leak test procedure (standard system)
The fuel-gas system has 2 automated leak test modes. See Automated diagnostic tests in this section.
Leak test for a standard system (no fuel-gas console)
1. Turn ON the power to the system.
2. After the initial gas purge, move the process selection switch to SET.
3. Adjust the air supply regulator to 5.5 bar (80 psi).
4. Adjust the O
2
supply regulator to 5.5 bar (80 psi).
5. Move the process selection switch to RUN.
6. Disconnect the off-valve cable (1x3)
from the rear panel of the power supply.
7. Move the process selection switch to SET.
8. Turn off the oxygen and the air at the supply.
9. Monitor the plasma pressure and the shield pressure displays for 10 minutes. The pressure should not decrease
more than 0.7 bar (10 psi) in 10 minutes.
10. When the test is complete, reconnect the 1x3 cable, move the process selection switch to RUN, and reset the
incoming gas supply pressures.
1
X
3
- EDGE Pro Ti Shape Cutting Control Rev.2 (288 pages)
- 80669J Rev.3 (304 pages)
- HD3070 Plasma Arc Cutting System w/ Manual Gas Console (281 pages)
- MAXPRO200 Rev.2 (294 pages)
- MicroEDGE Pro Shape Cutting Control Rev.2 (182 pages)
- HPR260 Auto Gas Preventive Maintenance Program Rev.4 (288 pages)
- Powermax1650 (317 pages)
- Shape Cutting Control (66 pages)
- PHC Sensor (58 pages)
- HTA Rev 6.00 Operators Manual (212 pages)
- HTA Rev 7.00 Install Guide (242 pages)
- THC Control Board Replacement (13 pages)
- THC Plasma Interfacer Upgrade (9 pages)
- THC X-Y Table Product Configuration (20 pages)
- D845GERG2 (128 pages)
- MRT2 (64 pages)
- MRT (98 pages)
- Duramax Hyamp Long Handheld Torches (92 pages)
- Duramax Hyamp Robotic Torch (74 pages)
- HyIntensity Fiber Laser Rev.3 (240 pages)
- PCBS-0124 (70 pages)
- SuperMicro 370SBA 533Mhz (90 pages)
- LR2075 (56 pages)
- Phoenix 8.0 (585 pages)
- LH2125 (60 pages)
- HD3070 w/ Automatic Gas (35 pages)
- HD3070 w/Manual Gas (43 pages)
- HD4070 Rev.8 (278 pages)
- HD4070 Product Configuration (88 pages)
- HPR800XD Manual Gas Preventive Maintenance Program Rev.1 (32 pages)
- HPR800XD Manual Gas Preventive Maintenance Program Rev.1 (33 pages)
- HPR800XD Manual Gas Rev.2 (368 pages)
- HPRXD Short Torch with Integrated Lead Rev.1 (30 pages)
- HT4001 (59 pages)
- DuraChill 5 HP Air-Cooled Chiller For Hypertherm (29 pages)
- HT4001 Air Injected Water Muffler System (40 pages)
- H601 Power Supplies (62 pages)
- MAX200 Remote Switch (9 pages)
- HT4100 Plasma Arc Cutting System Operating (50 pages)
- HT4001 Plasma Arc Cutting System (259 pages)
- HySpeed HT2000 Plasma Arc Cutting System Rev.7 (53 pages)
- HySpeed HT2000 Plasma Arc Cutting System Rev.27 (289 pages)
- MAX200 Water Muffler (39 pages)
- HT2000LHF Product Configuration (23 pages)