beautypg.com

Mild steel, Air plasma / air shield 130 a cutting, Metric – Hypertherm HSD130 HySpeed Plasma User Manual

Page 126: English

background image

OPERATION

4-12

HySpeed HSD130 RHF

Instruction Manual

Mild steel

Air Plasma / Air Shield

130 A Cutting

220536

220492

220488

220487

Metric

Plasma

Shield

Plasma

Shield

mm

Volts

mm

factor %

seconds

3

136

6.2

200

0.1

4

13

6.2

200

0.2

6

138

7.2

200

0.3

10

142

8.2

200

0.5

12

144

8.2

200

0.5

15

150

9.2

200

0.8

20

153

10.5

230

1.2

25

163

32

170

English

Plasma

Shield

Plasma

Shield

in

Volts

in

factor %

seconds

0.1350

136

.240

200

0.1

0.1875

136

.240

200

0.2

0.2500

138

.280

200

0.3

0.3750

142

.320

200

0.5

0.5000

144

.320

200

0.5

0.6250

150

.360

200

0.8

0.7500

153

.420

230

1.2

1

163

1-1/4

170

Edge Start

Edge Start

72

35

72

35

4.6

4.6

5.1

15

.180

.180

2050

1450

810

410

6000

4930

3850

2450

.200

220

160

150

100

75

50

35

10

Initial Pierce Height

Select
Gases

Set

Cutflow

Initial Pierce Height

250

3.1

3.1

3.6

4.1

4.1

Cutting Speed

.120

.120

.140

.160

.160

.180

Pierce Delay

Time

mm

mm/m

Air

Air

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting Speed

4.6

Pierce Delay

Time

in

ipm

Air

Air

Select
Gases

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Flow Rates – lpm/scfh

Air

Preflow

67 / 142

Cutflow

132 / 280

220578

220490 (no IHS tab)