Mild steel, Plasma / air shield 50 a cutting, Metric – Hypertherm HSD130 HySpeed Plasma User Manual
Page 125: English

OPERATION
HySpeed HSD130 RHF
Instruction Manual
4-11
Mild steel
O
2
Plasma / Air Shield
50 A Cutting
Flow Rates – lpm/scfh
O
2
Air
Preflow
0 / 0
69 / 146
Cutflow
29 / 62
73 / 155
220532
220530
220529
220528
Metric
Plasma
Shield
Plasma
Shield
mm
Volts
mm
factor %
seconds
0.5
98
3.0
200
0.0
0.8
98
3.0
200
0.0
1.0
98
3.0
200
0.1
1.2
98
3.0
200
0.1
1.5
98
3.0
200
0.1
2.0
98
3.0
200
0.1
2.5
100
3.6
200
0.2
3.0
102
3.6
200
0.3
4.0
104
4.0
200
0.4
6.0
108
5.0
200
0.5
English
Plasma
Shield
Plasma
Shield
in
Volts
in
factor %
seconds
.018
98
0.120
200
0.0
.024
98
0.120
200
0.0
.030
98
0.120
200
0.0
.036
98
0.120
200
0.1
.048
98
0.120
200
0.1
.060
98
0.120
200
0.1
.075
98
0.120
200
0.1
.105
100
0.140
200
0.2
.135
103
0.140
200
0.3
3/16
106
0.180
200
0.4
1/4
108
0.200
200
0.5
72
36
85
65
240
220
160
130
290
280
270
260
3650
2800
1750
300
6600
6150
5400
4300
.090
.100
1.5
1.5
1.5
1.5
1.5
1.5
1.8
1.8
.060
.060
.070
.070
O
2
Air
.060
.060
.060
.060
.060
Material
Thickness
Pierce Delay
Time
in
ipm
Arc
Voltage
Torch-to-Work
Distance
Initial Pierce Height
O
2
Air
Select
Gases
Set
Cutflow
72
36
Initial Pierce Height
Pierce Delay
Time
Select
Gases
Set
Cutflow
Material
Thickness
Arc
Voltage
mm
mm/m
Cutting Speed
Torch-to-Work
Distance
Cutting Speed
2.0
2.5
7550
7050
6775
220578
220490 (no IHS tab)