Guralp Systems CMG-6TD User Manual
Page 36

Installing the 6TD
exposed on the instrument's main connector. If you have problems
connecting to the 6TD over a network, you can attach a diagnostics cable,
CAS-PEP-0041, to this port and use Scream! to access the console.
Channel 2 (port 10,002) is connected to the 6TD's digital output, unless
you have connected a serial data cable from the breakout box to a
computer. If the breakout box is connected, the 6TD will send data
streams through that interface rather than to the Wi-Port-NR.
Click on Channel 2 – Serial Settings.
Set the Baud Rate to 19200. This is the default baud rate for the 6TD's
digital output.
Note: If you change the baud rate in Scream! or using the
terminal, you must come back to this page and change the
Baud Rate setting.
The remaining settings can be left at their default values. Click
to save your changes.
For full information on the Wi-Port-NR's configuration options, please
refer to the Wi-Port documentation, which is available on the Lantronix
3. When you have finished setting up the Wi-Port-NR, apply the new
settings by clicking
. The Wi-Port-NR will
re-boot with the new settings in effect.
Note: Simply changing settings in the web page and clicking
does not effect any functional change. You must
click
before the changes take effect.
If the Wi-Port-NR is using an automatically chosen random IP
(beginning with 169.254), the IP address will change when you do this.
You will need to go back to DeviceInstaller to find out the new IP
address.
36
Issue F - February 2014