10 specifications – Guralp Systems CMG-6TD User Manual
Page 107

Specifications
10 Specifications
Outputs and
response
Sensitivity
2000 V/m/s
Nominal output sensitivity
2.0 × 10
-9
m/s/count
Standard output format
24-bit
Noise-free resolution (NPR) at 20
samples/s
> 132 dB r.m.s.
(> 22 bits)
Standard frequency band
0.033 Hz (30 s) – 100 Hz
Digital signal processor
TMS3200 at 144 MHz
Output rate
User selectable
RS232 baud rate
User selectable
Physical
Lowest spurious resonance
450 Hertz
Operating temperature range
–10 to +75 °C
Pressure jacket material
hard anodised
aluminium
Internal thermometer accuracy
±0.33 °C (30 °C)
±0.5 °C (10..50 °C)
±1.0 °C (–10..75 °C)
Internal thermometer linearity
±0.5 °C
Internal thermometer resolution
0.0625 °C
Sensor base plate
hard anodised
aluminium
Base diameter
154 mm
Sensor height
242 mm (including
handle)
Sensor weight
3.0 kg
Power
Voltage requirements
10..24 V using 12 V
DC/DC converter
Current at 12 V DC with GPS
165 mA
107
Issue F - February 2014