Appendix: Totalizer Display Information
Appendix: Totalizer Display Information
By activating the magnet located at the opposite side of the totalizer, various information will
appear on the display as follows:
Information Type
Definition
Example of Display
Volume
Displays uncompensated volume
Probe Temperature
Displays probe temperature (in Celsius only)
Flow Rate
Displays flow rate (in LPM only)
Software Version
Displays software version number
ATC Status
Displays ATC status
Leftmost digits (842) are error indicators which are blank when
the corresponding error condition is not active.
8 = temperature probe fault detected
4 = pulser error occured
2 = exceptional reset detected
Rightmost digit (2) indicates whether temperature compensation
is enabled, and if so, what product is being dispensed.
0 = temperature compensation disabled
1 = product is gasoline and compensation enabled
2 = product is diesel and compensation enabled
0023.43
0 23.2
189.2
1.30
842 .2