Remount the LP-70 Polycase box cover removed in step 1.
29
Using two of the crimp splices, connect the two yellow wires extending from the bottom of the
IS barrier mounting stud to the two blue wires attached to the single probe connector assembly.
30
Using two OM0205 caps or suitable-size wire nuts (OM0205 caps or wire nuts are not part of
the kit.), cap the end of the two green wires extending from the bottom of the IS barrier.
31
In the kit, locate the following: (See
for parts identity)
• W199 probe assembly
• BC407 Thermowell
• 235-C Thermowell Plug
• BC546 Adapter
32
Underneath the shelf (where the IS barrier is mounted), locate the two plugs in the hydraulic
coupling (
Figure 11: Probe Assembly Mounting Location
33
Using the appropriate size Allen wrench, remove the two plugs.
4
Not used
5
Pulser Multiplier
ON for 9850, OFF for 9852/9853
6
Number of Probes
ON for two (2) probes, OFF for one (1) probe
7
Pulser Adder
ON for 9840
8
ATC
ON for ATC ON, OFF for ATC OFF
DIP Switch Settings
Switch
Number
Switch Function
Settings
Plugs