Preparing for the installation, Installing the conversion kits (m0639k00x), Caution – Gasboy Hi-Flow Sat Pipng Conversion Kits User Manual
Page 6

Installing Atlas Hi-Flow Satellite Conversion Kits M06391K001, K002, K003 and K004
Page 6
MDE-4514 Instructions for Installing Atlas™ Hi-Flow Satellite Piping Conversion Kits M06391K00X • June 2006
Installing Atlas Hi-Flow Satellite Conversion Kits
M06391K001, K002, K003 and K004
To install Atlas Hi-flow with the Satellite conversion kit, proceed as follows:
Preparing for the Installation
Bleed pressure prior to disassembly and wear proper eye protection
.
CAUTION
!
1
Close and test shear valves. Run the unit to bleed off pressure and drain the fuel into an
approved container.
2
Request permission from the manager/owner to remove power from the unit and then remove
power using normal procedures. Perform the lockout/tagout safety procedures.
3
Ensure that you have the proper kit for the model dispenser to be retrofitted.
4
Follow all applicable safety rules and procedures.
Installing the Conversion Kits (M0639K00X)
Removing the Existing Solenoid Valve and Discharge Line
1
Remove the exterior discharge fitting and any grommet. Residual pressure may exist. Wear
eye protection.
2
Remove and retain the two screws holding the discharge casting to the bottom of the meter.
Remove the discharge casting and the attached discharge piping. Collect fuel in an approved
container, clean up any spills and dispose properly.
3
Disconnect the solenoid valve wiring in the junction box. Mark the connections in the junction
box for all wires connected to the solenoid valve, so that the valve replacement can easily be
connected to the correct wires.
4
Disconnect the feedline from the solenoid valve/filter manifold on the meter. Disconnect the
valve conduit union.
5
Loosen but do not remove the nut holding the meter stabilizer bracket to the frame so that the
bracket can be maneuvered to permit removal of the valve/filter manifold. Remove the
solenoid valve/filter manifold from the meter and pull the coil wires through the conduit.
Retain the mounting hardware.