beautypg.com

Modifying the side sheathing for the discharge, 2 remove the sheathing from the unit, Warning – Gasboy Hi-Flow Sat Pipng Conversion Kits User Manual

Page 10

background image

Installing Atlas Hi-Flow Satellite Conversion Kits M06391K001, K002, K003 and K004

Page 10

MDE-4514 Instructions for Installing Atlas™ Hi-Flow Satellite Piping Conversion Kits M06391K00X • June 2006

4

Route the valve coil wires into the junction box. Attach the conduit to the fitting in the
junction box and tighten them.

5

Check discharge piping alignment and adjust as needed. Attach the satellite piping support
bracket (

Figure 4

) to the dispenser inlet support plate, insert and tighten the two M8 thread

forming screws.

6

Insert the U-bolt (

Figure 4

) around the pipe elbow and through the slots on the support bracket.

Attach two nuts and tighten all fasteners.

7

Stuff a clean rag into the elbow on the top end of the discharge line and proceed to

“Modifying

the Side Sheathing for the Discharge” on page 10

.

Modifying the Side Sheathing for the Discharge

See

Figure 5 on page 11

.

The use of power tools or any means to cut the sheathing hole (step

3

) with flammable

fuels or vapors present is hazardous and can result in fire or explosion causing serious
injury or death.

Remove the sheathing from the unit and transport to a safe distance from potentially
hazardous locations to cut the sheathing hole.

WARNING

!

1

Mark the location of the discharge elbow on the side sheathing as shown in

Figure 5 on page

11

. Check the dimensions against the location of the discharge elbow in the assembly to ensure

that the marked location is correct. Adjust the mark, if necessary.

2

Remove the sheathing from the unit.