Modifying the side sheathing for the discharge, 2 remove the sheathing from the unit, Warning – Gasboy Hi-Flow Sat Pipng Conversion Kits User Manual
Page 10

Installing Atlas Hi-Flow Satellite Conversion Kits M06391K001, K002, K003 and K004
Page 10
MDE-4514 Instructions for Installing Atlas™ Hi-Flow Satellite Piping Conversion Kits M06391K00X • June 2006
4
Route the valve coil wires into the junction box. Attach the conduit to the fitting in the
junction box and tighten them.
5
Check discharge piping alignment and adjust as needed. Attach the satellite piping support
bracket (
) to the dispenser inlet support plate, insert and tighten the two M8 thread
forming screws.
6
Insert the U-bolt (
) around the pipe elbow and through the slots on the support bracket.
Attach two nuts and tighten all fasteners.
7
Stuff a clean rag into the elbow on the top end of the discharge line and proceed to
the Side Sheathing for the Discharge” on page 10
Modifying the Side Sheathing for the Discharge
The use of power tools or any means to cut the sheathing hole (step
) with flammable
fuels or vapors present is hazardous and can result in fire or explosion causing serious
injury or death.
Remove the sheathing from the unit and transport to a safe distance from potentially
hazardous locations to cut the sheathing hole.
WARNING
!
1
Mark the location of the discharge elbow on the side sheathing as shown in
. Check the dimensions against the location of the discharge elbow in the assembly to ensure
that the marked location is correct. Adjust the mark, if necessary.
2
Remove the sheathing from the unit.