beautypg.com

Gasboy Totalizer Retro User Manual

Page 9

background image

MDE-4511B Retrofit Kits for Atlas™ Electro-mechanical and Commercial Electronic Units Installation Instructions · June 2011

Page 9

Installation

On both sides of the unit, place a N23140-01 decal (arrow), which is part of the kit, on the
bezel face to the left of the totalizer opening. Orient the arrow pointing to the left (away from
the totalizer opening). On Side A of the unit the arrow is pointing toward Side 1. On Side B of
the unit, the arrow is pointing toward Side 2.

Installing the DC Conduit (Commercial Unit Only)

Note: If you already have a DC conduit installed and the harness does not match the harness

provided with this kit, then remove the DC conduit and install the DC conduit supplied
with this kit.

To install the DC conduit, proceed as follows:

1

Remove the cover mounting screws and the cover at the junction box.
Note: Retain screws for remounting the cover.

2

Insert and tighten the Reducer (K49827) in the opening (location of the opening is shown in

Figure 3

).

Note: As a reminder, the conduit threads engage a minimum of five threads.

Figure 3: Junction Box Connections

Reducer (K49827)

Union (Q10016-04)

Shield (M05235B001)

Shield Mounting Screw
(M00417B224)

3

Insert the Conduit Union (Q10016-04) in the reducer installed in step

2

.

Note: When performing steps

4

through

8

on

page 10

,

ensure that

you hold the conduit in

place when mounting washers until it is connected to the union at the junction box.

4

Route the straight end of the conduit through the lower barrier plate. For conduit and washer
placement for steps

4

through

6

, see

Figure 4

on

page 10

.

5

Place a washer on the conduit (in the air gap).

6

Continue routing the conduit through the upper barrier plate.