Page 17

Installing Atlas 9800 Pulse-out I/F with EM Totalizer Drive Board (M06587A001)

Installing Atlas 9800 Pulse-out I/F with EM Totalizer Drive
Board (M06587A001)

JP1, JP2, and JP3

This board assembly can be configured for use in one of the following pump/dispenser
configurations:

• Dual Channel, Single Hose Pulse-out I/F (see

Figure 6

on

page 18

)

• Single Channel, Dual/Single Hose Pulse-out I/F (see

Figure 7

on

page 18

)

• Dual Channel, Dual Hose Pulse-out I/F (see

Figure 8

on

page 18

)

Following table shows the jumper settings and wires to connect to in the J-box, based on the
configuration.

Check JP1 - JP3 jumpers and change them, if required. The jumper settings must be changed
only when the power to the pump/dispenser is removed, to protect the circuit that they are
connected to.

Default configuration is Single Channel, Dual/Single Hose Pulse-out I/F. When configured for
Dual Channel, Single Hose Pulse-out I/F, or Single Channel, Dual/Single Hose Pulse-out I/F,
the P3 Connector is not connected.

When configured for Dual Channel, Dual Hose Pulse-out I/F, the P3 Connector is used.

Jumper Settings

Single Channel, Dual/Single
Hose Pulse-out I/F
(Default Setting)

Dual Channel, Single Hose
Pulse-out I/F

Dual Channel, Dual Hose
Pulse-out I/F

Wire Color

JP1 Position 1
JP2 Position 1
JP3 Open

JP1 Position 2
JP2 Position 2
JP3 Open

JP1 Position 2
JP2 Position 2
JP3 Jumpered

Red

Pulse out Side 1

Pulse out Side1A

Pulse out Side 1A

Green

Pulse out Side 2

Pulse out Side1B

Pulse out Side 1B

White

Common Return

Side 1A Return

Side 1A Return

Black

No Connection

Side 1B Return

Side 1B Return

Brown

No Connection

No Connection

Pulse out Side 2A

Orange

No Connection

No Connection

Pulse out Side 2B

Yellow

No Connection

No Connection

Side 2A Return

Gray

No Connection

No Connection

Side 2B Return

JP4 and JP5

When this board is used in a model A or Q pump/dispenser or 9850K, jumpers JP4 and JP5 are
set to the Q/A position. When this board is used for all other K models except 9850K, these
jumpers must be in the K position.