MDE-4652D Atlas™ 9800 Electronics Field Installation Instructions · April 2013

Page 15

Installing Atlas 9800 CPU Board (M06333KXXXX)

Leading zeros are always suppressed in the tens and hundreds place to the left of the decimal
point. In Standalone mode, positions to the right of the decimal point are displayed based on
the pulse output rate and unit of measure selected. However, in case of 9850, the model is
displayed.

Pulse Rate

Gallons - US or Imperial Liters and/or 9850

1:1

XXX

XXXX

10:1

XXX.X

XXXX.X

100:1

XXX.XX

XXXX.XX

250:1

XXX.XXX

XXXX.XX

500:1

XXX.XXX

XXXX.XX

Timeout Switch (if JP2 is Jumpered)
When the pump/dispenser is in the Standalone mode, including Pulse-out I/F configurations, it
will turn off an active hose outlet if it does not detect input pulses for 4 minutes and 15
seconds.

Timeout

SW2-4

Enabled

Closed

Disabled

Open

SW2-5 and SW2-6 - Unit of Measure Selection

These two switches set the unit of measure (US gallons, liters, or Imperial gallons) that the
pump/dispenser will use to meter fuel.

Unit of Measure

SW2-5

SW2-6

US Gallons

Closed

Closed

Liters

Open

Closed

Imperial Gallons

Closed

Open

NOT USED (default US Gallons) Open

Open

SW2-7 - EM Totalizer Enable

This switch is only used on K model pumps/dispensers (excluding the 9850K model). When
closed (“On”), it enables the pump/dispenser to drive electro-mechanical totalizers used on
some K models pump. On A and Q models, this switch is ignored.

EM Totalizer

SW2-7

Enabled

Closed

Disabled

Open

SW2-8 - BDM Enable

This switch must be open for normal operation.

SW2-9 - Software Load Enable

This switch must be open for normal operation. When this switch is closed, it enables loading
the new software (refer to

“Loading New CPU Software”

on

page 19

).

SW2-10

This switch is not used (or close it to ground input).