Installing Atlas 9800 CPU Board (M06333KXXXX)

Page 14

MDE-4652D Atlas™ 9800 Electronics Field Installation Instructions · April 2013

Pulse Output Rate Switches (if JP2 is Jumpered)
When the pump/dispenser is connected to an external controlling equipment that requires
pulse output signals (for example, Gasboy Series 1000), the pulse signals are sent through the
Pulse-out I/F Board. Setting Switches SW2-1 through SW2-3 configures the Pulse-out rate
required by the monitoring equipment. Pulse-out rate represents the pulses per unit (gallon,
liter, or imperial gallon).

Pulse Rate SW2-1

SW2-2

SW2-3

1:1

Closed

Closed

Closed

10:1

Open

Closed

Closed

100:1

Closed

Open

Closed

250:1

Open

Open

Closed

500:1

Closed

Closed

Open

None

Open

Closed

Open

None

Closed

Open

Open

None

Open

Open

Open

Maximum pulse output rate that can be achieved depends on the model of the pump/dispenser
and the unit of measure. Pulse output rate of 1000:1 is not supported when using the CPU
Board.

Note: 9800 refers to models 9852, 9853, 9822, and 9823.

Unit of Measure 9800 Models 9840A/Q Models

9840K Models

9850 Models

US Gallons

500:1

500:1

500:1

100:1

Liters

100:1

100:1

10:1

10:1

Imperial Gallons

500:1

500:1

500:1

100:1

Note: If a valid pulse-out rate is not selected, the CPU will not output pulses.

5

Closed

Closed

Open

Closed

6

Open

Closed

Open

Closed

7

Closed

Open

Open

Closed

8

Open

Open

Open

Closed

9

Closed

Closed

Closed

Open

10

Open

Closed

Closed

Open

11

Closed

Open

Closed

Open

12

Open

Open

Closed

Open

13

Closed

Closed

Open

Open

14

Open

Closed

Open

Open

15

Closed

Open

Open

Open

16

Open

Open

Open

Open

Address

SW2-1

SW2-2

SW2-3

SW2-4