You can select:
- Feed Always or not. If you select Off, the unit is disused until it is turned back
on again.
- Whether doubles detection is turned on or off. Turn off if booklets or very thick
inserts are being fed. If turned on, select whether Optical or Mechanical detection,
or Auto (software decides).
- Optical doubles sensitivity (valid only if Optical Doubles On is selected). Low
set-ting is more tolerant to high contrast printing.
- Amount of deskew; use higher settings only when necessary – machine operates
faster on lower settings.
- Only for Reading units. Reset Seq. Count - if Sequence OMR marks are being
used and the job is disrupted for any reason, select this button to reset the
sequence.
- Only for Reading units. Retrieve CIS Image - if selected, images of the label
as seen by the CIS reader will be displayed. The images will be of the final 2
documents in the group and can be useful for error checking by confirming that
the whole label was read, for example, or comparing the 2 images.
-