beautypg.com

6 initial operation information, Initial operation information -8 – Daktronics AE-3010-7.6-R,G,A User Manual

Page 38

background image

Maintenance and Troubleshooting

4-8

Cannot communicate to section of
the network of displays

Check the cabling between displays.

Check for bad input on first bad display.

Check for bad output on the last good
display.

Switch the suspected bad display with
a known good display.

Check displays and software for correct
addressing

Display is stuck on bright or dim.

Check Manual/Auto dimming in Venus
1500 software.

Check light detector cable.

Replace light detector.

Replace controller board.

4.6 Initial Operation Information

Each time the display is powered up, the display will run through an initialization in
which it will display the following:

1. Output Test (DDD’s)
2. Product Name (Galaxy)
3. Display Size (Row x Column)
4. Firmware Number (ED10134)
5. Firmware Revision (Rev X.XX)
6. COM1 Configuration (C1: V15/RTD)
7. COM2 Configuration (C2: None)
8. Line Frequency (60 Hz)
9. Hardware Address (HW: XX)
10. Software Address (SW: XX)
11. Display Name
12. If Modem is Present (Modem)