Comtech EF Data MBT-5003 User Manual
Page 91

MBT-5003 L-Band Up/Down Converter System
Revision 1
Appendix A
MN-MBT5003
A–15
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes
between 48 and 57)
Response to
Command
(Target to
controller)
Query
(Instruction
Code and
qualifier)
Response to query
(Target to controller)
Retrieve Next
5
unread stored
Statistics
N/A variable
length
Query only.
Unit returns the oldest 5 Stored Statistics entries which have not
yet been read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body=
ddmmyyhhmmssaaa.abbb.bccc.cddd.dee.eeff.ffghijkk.kll.l
ddmmyy = day/month/year
hhmmss = hour:minute:second
aaa.a = Conveter A Operating Temperature
bbb.b = Conveter B Operating Temperature
ccc.c = Converter A RF Power output
ddd.d = Converter B RF Power output
ee.ee = Converter A Attenuation Setting
ff.ff = Converter B Attenuation Setting
g = Converter A Mute On/Off
h = Converter B Mute On/Off
i = Converter A Online/Offline Status
j = Converter B Online/Offline Status
kk.k = Converter A Tuning Voltage
ll.l = Converter B Tuning Voltage
If there are less than 5 entries to be retrieved, the remaining
positions are padded with zeros.
If there are no new entries, the response is RNS*.
N/A RNS?
RNS={CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-body
(See Description of
Arguments)
Remote Baud
Rate
SBR= 4
bytes Command or Query.
Set remote baud rate as follows:
2400 = 2400 baud
4800 = 4800 baud
9600 = 9600 baud
19K2 = 19200 baud
38K4 = 38400 baud
Default Value: 9600
Example: <1/SBR=9600’cr’
>0001/SBR=9600’cr’’lf’
Note: When changing baud rates remotely the response to the
command will be returned using the same baud rate as that used
to send the command.
SBR=
SBR?
SBR?
SBR=xxxx
(Same format as command
arguments)