MBT-5003 L-Band Up/Down Converter System
Revision 1
Front Panel Operation
MN-MBT5003
5–11
5.3.2
SELECT: Monitor
Note: Low Noise Amplifier (LNA) operation is not supported by the MBT-5003. The LPT
selection on this submenu is therefore nonfunctional.
Monitor: Faults Mask
Event-Log LPT
Use the
◄ ►
arrow keys to select from the submenu choices shown, then press ENT. The following
table identifies each submenu available from the SELECT: Monitor menu branch – typical for
Converter Unit A or Unit B – its content section in this chapter, and functional description of each
submenu:
Submenu
Sect
Functional Description
Faults
5.3.2.1
Displays the active faults for the base unit and the converters.
Mask
5.3.2.2
Permits the user to configure Alarm Mask (MSK) conditions.
Event-Log
5.3.2.3
Display stored events. Also permits the user to clear the events.
5.3.2.1
MONITOR: Faults
Live Faults: Unit ConvA
ConvB (◄ ► E)
Select Unit, ConvA, or ConvB using the
◄ ►
arrow keys, then press ENT.
If Unit is selected, the highest level fault for the base unit will appear. If no Unit faults exist,
the message “
No Errors
” is displayed:
Unit Fault:
No Errors
Press ENT to return to the previous menu.
If ConvA or ConvB is selected, the highest fault for the converter will appear. If no converter
faults exist, the message “
No Errors
” is displayed:
ConvA Fault:
No Errors
Press ENT to return to the previous menu.
5.3.2.2
MONITOR: Mask
Note: The Power selection on this submenu is operable only when the MBT-5003-XUR is
optionally configured with the Power Monitor option. Low Noise Amplifier (LNA) operation is
not supported by the MBT-5003 – the LNA selection is therefore nonfunctional.
Alarm Mask: Power ExtRef
ConvA ConvB LNA (◄ ► E)