Comtech EF Data MBT-5003 User Manual
Page 90
MBT-5003 L-Band Up/Down Converter System
Revision 1
Appendix A
MN-MBT5003
A–14
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes
between 48 and 57)
Response to
Command
(Target to
controller)
Query
(Instruction
Code and
qualifier)
Response to query
(Target to controller)
Retrieve Next
5 unread
stored Events
N/A 75
bytes
Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body= ABCddmmyyhhmmss:
A being the fault/clear indicator.
F = Fault
C = Clear
I = Info
B being the fault type where:
1 = Base Unit
2 = Converter A
3 = Converter B
C is Fault Code numbers
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
N/A RNE?
RNE={CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss{CR}ABCddmmyyhh
mmss
(See Description of
Arguments)