MBT-5003 L-Band Up/Down Converter System

Revision 1

Appendix A

MN-MBT5003

A–12

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes

between 48 and 57)

Response to

Command

(Target to

controller)

Query

(Instruction

Code and

qualifier)

Response to query

(Target to controller)

Unit Alarm
Mask

MSK= 5

bytes Command or Query.

Alarm mask conditions. If an alarm is masked, neither an alarm or a
fault is set, and the user will not know of a problem. Form of abcd,
where:
0 = Alarm, 1 = Fault, 2 = Masked

a = Low Forward RF Power
b = External Reference Lock detect
c = Converter A Not Inserted
d = Converter B Not Inserted

Default value: 2200.

There could be a variable delay in the time it takes for the internal
reference to lock to an external reference, due warm-up
characteristics and frequency differences between the references.
Therefore, the default setting is "masked" for the reference lock
detect. This setting may be changed if the customer so desires.
The delay should be less than 1 s after 30 minutes of warm-up
time.

MSK=
MSK?
MSK*

MSK? MSK=abcde


(See Description of
Arguments)

Number of
Unread stored
Events

N/A 3

bytes

Query only.
Unit returns the Number of stored Events, which remain Unread in
the form of xxx.

Example: NUE=126

N/A NUE?

NUE=xxx

Number of
Unread stored
Statistics

N/A 3

bytes

Query only.
Unit returns the Number of stored Statistics, which remain Unread
in the form of xxx.

Example: NUS=126

N/A NUS?

NUS=xxx

Part Number

N/A

Various 1-96
bytes

Query only.
Returns the Comtech EF Data part number of the unit. This part
number is the unit’s DOTCODE at the time it was manufactured.
The DOTCODE may be up to 96 printable ASCII characters long.

Example: <1/PNM?’cr’
>0001/PNM=MBT5003.350WRSW00’cr’’lf’

N/A PNM?

PNM=x….x


(See Description of
Argumen ts for return string
details)

Reboot RBT= 1

byte Command only.

Soft Reboot
1 = Reboot System

RBT =
RBT?
RBT*

N/A RBT=x


(See Description of
Arguments)