MBT-5003 L-Band Up/Down Converter System
Revision 1
Installation
MN-MBT5003
2–3
2.2.2 Installation Using Optional Bearingless Rack Slide Set
If the converter is to be mounted on slides, install the optional bearingless rack slide set FP/SL0006
(Figure 2-2) using both included and user-provided mounting hardware:
Install the components of the rack slide set as follows:
Step
Procedure
1
Using the provided mounting hardware, install the rack slides to either side of the
MBT-5003 chassis.
2
Using the provided mounting hardware, install the slide rail components into each
side of the rack cabinet.
3
Mount the unit into the equipment rack, ensuring that the slides properly engage the
cabinet-mounted slide rails.
4
Slide the unit into the rack cabinet until the front panel’s back surfaces abut the rack
cabinet’s front mounting rails.
5
Secure the unit to the rack cabinet front mounting rails using four user-provided
screws installed through the front panel mounting slots.
CEFD Part Number
Description
FP/SL0006
Bearingless Rack Slide Set – 26”
Figure 2-2. Optional Bearingless Rack Slide Installation (FP/SL0006)