Comtech EF Data MBT-5003 User Manual
Page 85
MBT-5003 L-Band Up/Down Converter System
Revision 1
Appendix A
MN-MBT5003
A–9
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes
between 48 and 57)
Response to
Command
(Target to
controller)
Query
(Instruction
Code and
qualifier)
Response to query
(Target to controller)
Enable
Statistics
Averaging
ESA= 1
byte Command or Query.
Enables or Disables averaging of statistics data at a rate of once
per second for 10 second. If Disabled, burst values will be logged
instead of averaged values.
0 = Disabled
1 = Enabled
Default Value: 0
Example: <1/ESA=0’cr’
>0001/ESA=’cr’’lf’
ESA=
ESA?
ESA? ESA=x
(Same format as command
arguments)
Enable
Statistics
Logging
ESL= 1
byte Command or Query.
Enables or Disables the statistics logging function.
0 = Disable
1 = Enable
Default Value: 0
Example: <1/ESL=1’cr’
>0001/ESL=’cr’’lf’
ESL=
ESL?
ESL? ESL=x
(Same format as command
arguments)
Enable
Redundancy
Switch Mode
ESW= 1
byte Command or Query.
Turns ON or OFF the redundancy state, where:
0 = Off
1 = On
Default value: 1
Example: <1/ESW=1’cr’
>0001/ESW=’cr’’lf’
ESW=
ESW?
ESW *
ESW? ESW=x