Page 22: 3 monitor & control, 4 reference
MBT-5003 L-Band Up/Down Converter System
Revision 1
Introduction
MN-MBT5003
1–6
1.4
Summary of Specifications
1.4.1
Physical & Environmental
Weight
20 lbs. (9.07 kg) Nominal
Dimensions (excluding connectors)
19” x 5.25” x 14” (482.6 x 133.35 x 355.6 mm) (See Figure 1-3)
Temperature
Operating
32º to 132.8ºF (0º to 56ºC)
Non-operating (Storage)
-58º to 158ºF (-50º to 70ºC)
Operational Altitude
15,000 ft above sea level
Shock
Normal commercial shipping and handling
1.4.2
Prime Power
AC Input
IEC-320 w/retainer
Voltage
AC
90 – 260 VAC
DC (optional)
48 VDC
Frequency
47 – 63 Hz
Dissipation
Up converter
100 Watts, typical
Down converter
80 Watts, typical
1.4.3
Monitor & Control
Serial M&C Interface
TIA/EIA-485, 4-wire DB-9F
Alarm
Form C, DB-9F
Remote Interface
RJ-45 Ethernet
Physical Controls
6-button keypad entry
Display
Vacuum Fluorescent Display (VFD), 24x2 alphanumeric
Status Indicators
5 LEDs per unit: SUM FLT, MUTE, ONLINE, UP, DOWN
1.4.4
Reference
External Input
5 or 10 MHz 5
±5 dBm, BNC Female
Output
5 MHz 10
±5 dBm Front Panel, BNC Female
Internal 10 MHz
Stability over Time
±1 x 10
-9
/day (higher stability optional)
Stability over Temp
±1 x 10
-8
Setability
(by remote control)
Resolution
Better than 2.5 x 10
-8
Range
>
±5 x 10
-7