A.4 packet structure, A.4.1 start of packet – Comtech EF Data MBT-5003 User Manual
Page 79

MBT-5003 L-Band Up/Down Converter System
Revision 1
Appendix A
MN-MBT5003
A–3
A.4
Packet Structure
Controller-to-Target
Start of Packet
Target Address
Address Delimiter
Instruction Code
Code Qualifier
Optional
Arguments
End of Packet
<
ASCII code 60
(1 character)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
= or ?
ASCII codes 61 or 63
(1 character)
(n characters)
Carriage Return
ASCII code 13
(1 character)
Example: <0412/MUT=1{CR}
Target-to-Controller
Start of Packet
Target Address
Address Delimiter
Instruction Code
Code Qualifier
Optional
Arguments
End of Packet
>
ASCII code 62
(1 character)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
=, ?, !, or *
ASCII codes 61,63, 33
or 42
(1 character)
(From 0 to n
characters)
Carriage Return,
Line Feed
ASCII codes
13,10
(2 characters)
Example: >0412/MUT=1{CR}{LF}
A.4.1 Start of Packet
Controller-to-Target: This is the character '<' (ASCII code 60).
Target-to-Controller: This is the character '>' (ASCII code 62).
Because this is used to provide a reliable indication of the start of packet, these two characters may not appear anywhere else within the
body of the message.