Comtech EF Data MBT-5003 User Manual
Page 24
![background image](https://www.manualsdir.com/files/778947/content/doc024.png)
MBT-5003 L-Band Up/Down Converter System
Revision 1
Introduction
MN-MBT5003
1–8
1.4.6
BDC-5003 Block Down Converter (featured on MBT-5003-XDR)
Input Frequency
7250-7750 MHz
Output Frequency
1000-1500 MHz
Frequency Sense
No Inversion
Impedance
50
Ω
Input Return Loss
18 dB minimum
Output Return Loss
15 dB minimum
Input Connector
Type ‘N’ Female
Output Connector
Type ‘TNC’ Female
Gain
38
±2 dB nominal @ minimum attenuation
Full Band
±1.0 dB
Per 36 MHz
±0.50 dB
Per 20 MHz
±0.35 dB
0° to +56° C
.75 dB/15°C (
±1 dB, 0 to 56 °C)
Mute
-80 dBm
User Attenuation Range
0 to 20 dB, in 0.25 dB steps
Signal Level
10 dBm maximum (non-damage)
Output Power, P1dB
20 dBm minimum
Noise Figure
15 dB @ minimum attenuation
Intermodulation Distortion
-56 dBc w/2 carriers @ 0 dBm each, 3 dBm Total Output Pwr
AM/PM Conversion
0.1°/dB @ 0 dBm Output
Image Rejection
90dB
Spurious (In-band)
Carrier Related
-75 dBc (<-80 dBc typical)
Non-Carrier Related
-70 dBm
2
nd
Harmonic
-20 dBc maximum (-40 dBc typical)
Related
Lo Leakage
-75 dBm
60 Hz & Harmonics
<-36 dBc (typically <-50 dBc)
Phase Non-linearity
per 20 MHz BW
3 degrees p-p
per 36 MHz BW
4 degrees p-p
Phase Noise
Meets or exceeds MIL-STD-188-164A
100 Hz
-68 dBc/Hz
1 kHz
-78 dBc/Hz
10 kHz
-88 dBc/Hz
100 kHz
-98 dBc/Hz
1 MHz
-108 dBc/Hz