beautypg.com

Comtech EF Data SNM-1001 User Manual

Page 81

background image

Remote Control Operation

SNM-1001 Network Control Modem

A–22

Rev. 1

Current
Sweep
Value

Command:
Response:

>add/CSV_snnnnn'cr''lf']

Where:

x = < or > (data modifier to indicate that the sweep offset
value is less than or greater than the returned value).

s = + or - (sweep offset from center).

nnnnn = 0 to 35000.

Notes:

1. This command returns the current sweep offset value.
2. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

3. "No Data" is returned if the level cannot be calculated.
4. "Sampling" is returned if not enough data is currently

available to calculate the level.

Interface
Analog
Loopback
Jumper
Status

Status:
Response:

>add/ALBJ_xxx'cr''lf']

Where: xxx = ON or OFF.

Note: Only valid when ADPCM board is installed.