beautypg.com

Comtech EF Data SNM-1001 User Manual

Page 79

background image

Remote Control Operation

SNM-1001 Network Control Modem

A–20

Rev. 1

Automatic
Uplink
Power
Control
(AUPC)
Config
Status

Command:
Response:

>add/ACS_'cr'
LPC_xxx'cr'
NOMP_-nn.n'cr'
MINP_-nn.n'cr'
MAXP_-nn.n'cr'
ENSP_n.n'cr'
MAXT_n.n'cr'
LCL_xxxx'cr'
RCL_xxxx'cr'

Local AUPC Enable (ON/OFF)
Nominal Power Value (-5.0 to -30.0)
Minimum Power Limit (-5.0 to -30.0)
Maximum Power Value (-5.0 to -30.0)
E

b

/N

0

Target Set Point (3.2 to 9.7)

Max. Tracking Rate (0.5 to 6.0)
Local Carrier Loss (HOLD, NOM, MAX)
Remote Carrier Loss (HOLD, NOM, MAX)

The interface (AUPC) configuration status command causes a
block of data to be returned by the addressed modem. The
block reflects the current configuration of the interface.

Modem
Faults
Status
(Summary)

Command:
Response:

>add/MFS_'cr'
DMD_xxx'cr'
MOD_xxx'cr'
ITX_xxx'cr'
IRX_xxx'cr'
CEQ_xxx'cr''lf']

Demodulator (FLT/OK)
Modulator (FLT/OK)
Interface Transmit Side (FLT/OK)
Interface Receive Side (FLT/OK)
Common Equipment (FLT/OK)

Modulator
Status

Command:
Response:

>add/MS_'cr'
RF_xxx'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr'
SFLT_xx'cr''lf']

RF Output (ON/OFF) Actual Status Not Config
Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)
Number of Stored Faults Logged (0 to 10)

Demodulato
r Status

Command:
Response:

>add/DS_'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
DSCR_xxx'cr'
BERT_xxx'cr'
SFLT_xx'cr''lf']

Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
Descrambler (OK/FLT)
BER Threshold (OK/FLT)
Number of Stored Faults Logged (0 to 10)

Interface
Transmit
Side Status

Command:
Response:

>add/ITXS_'cr'
CLK_xxx'cr'
TAC_xxx'cr'

(See Note)

SFLT_xx'cr''lf']

Selected Transmit Clock Activity (OK/FLT)
Transmit Audio Clip (OK/FLT)
Number of Stored Faults Logged (0 to 10)

Note: Status only returned when ADPCM board is installed.

Interface
Receive
Side Status

Command:
Response:

>add/IRXS_'cr'
CLK_xxx'cr'
UNFL_xxx'cr'
OVFL_xxx'cr'
RAC_xxx'cr'

(See Note)

DMXL_xxx'cr'

(See Note)

SFLT_xx'cr''lf']

Selected Buffer Clock Activity (OK/FLT)
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Receive Audio Clip (OK/FLT)
Demultiplexer Lock (OK/FLT)
Number of Stored Faults Logged (0 to 10)

Note: Status only returned when ADPCM board is installed.