beautypg.com

Test points, 3 test points, 1 modulator test points – Comtech EF Data SNM-1001 User Manual

Page 51

background image

Maintenance

SNM-1001 Network Control Modem

5–6

Rev. 1

5.1.3 Test

Points

The modem does not have accessible test points. When troubleshooting is required at
board level, the cover must be removed.

The following is a list of test points located on the PCB, and a description of the signals
that should be present under normal operation.

5.1.3.1

Modulator Test Points

TP 1

DATA CLOCK

TTL level clock that is locked to the incoming data to the interface
card.

TP 2

SYMBOL CLOCK

TTL level clock that is locked to the incoming clock to the interface
card. This clock is running at the symbol frequency and not at the
data rate. The frequency is equal to:

BPSK = 2 x Bit Clock

QPSK1/2 = Bit Clock

QPSK3/4 = 2/3 Bit Clock

QPSK7/8 = 4/7 Bit Clock

TP 3

Q MIXER

Analog output of the Q channel baseband reconstruction filter and
the input to the RF modulator.

TP 4

Q DIGITAL FILTER

Analog output from the Digital filter.

TP 5

I DIGITAL FILTER

Analog output from the Digital filter.

TP 6

I MIXER

Analog output of the I channel baseband reconstruction filter and the
input to the RF modulator.