Page 66
SNM-1001 Network Control Modem
Remote Control Operation
Rev. 1
A–7
A.3.2 Demodulator
Set Demod
Frequency
Command:
Response:
Status:
Response:
Where: nnn.nnnn = Frequency in MHz, 50.0000 to
180.0000, in 2.5 kHz steps.
Demod
Rate Preset
Assignment
Command:
Response
Status:
Response:
Where:
x = A, B, C, D, or V (Preset designator).
nnnn = 1/2, 3/4, 7/8, or BP12 (Decoder rate).
mmm.mmm = Data rate in kHz.
Notes:
1. When ADPCM Interface is selected, only 32.000 and
64.000 are allowed.
2. When the Async Interface is used. If the ASYNC
baud rate is higher than allowable for the new data
rate, the maximum baud rate will be selected
automatically.
Demod
Rate Preset
Selection
Command:
Response:
Status:
See DR command.
Where: x = A, B, C, D, or V (Preset designator).
Demod
Rate
Variable
Assignment
& Selection
Command:
Response:
Status:
See DR command.
Where:
nnnn = 1/2, 3/4, 7/8, or BP12 (Decoder rate).
mmm.mmm = Data rate in kHz.
Notes:
1. When ADPCM Interface is selected, only 32.000 and
64.000 are allowed.
2. When the Async Interface is used. If the ASYNC
baud rate is higher than allowable for the new data
rate, the maximum baud rate will be selected
automatically.
Descramble
Enable
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
Differential
Decoder
Enable
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
RF
Loopback
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.
IF
Loopback
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF.