A.3 Configuration

Commands/Responses

A.3.1 Modulator

Modulator
Frequency

Command:
Response:

Status:
Response:

>add/MF_nnn.nnnn'cr'
RF_OFF'cr''lf']

>add/MF_nnn.nnnn'cr''lf']

Where: nnn.nnnn = Frequency in MHz, 50.0000 to
180.0000, in 2.5 kHz steps.

Note: When the modulator frequency is programmed, the
RF output is switched off.

RF Output
(IF Output)

Command:
Response:

Status:
Response:

>add/RF_xxx'cr''lf']

>add/RF_xxx'cr''lf']

Where: xxx = ON or OFF.

Modulator
Rate Preset
Assignment

Command:
Response

Status:
Response:

>add/AMRx_nnnn_mmm.mmm'cr''lf']

>add/AMRx_nnnn_mmm.mmm'cr''lf']

Where:

x = A, B, C, D, or V (Preset designator).
nnnn = 1/2, 3/4, 7/8, or BP12 (Coder rate).
mmm.mmm = Data rate in kHz.

Notes:

1. When ADPCM Interface is selected, only 32.000 and

64.000 are allowed.

2. When the Async Interface is used. If the ASYNC

baud rate is higher than allowable for the new data
rate, the maximum baud rate will be selected
automatically.

Modulator
Rate Preset
Selection

Command:
Response:

Status:

>add/SMRx_'cr'
RF_OFF'cr''lf']

See MR command.

Where: x = A, B, C, D, or V (Preset designator).

Note: Setting the modulator rate turns off the RF transmitter.

Modulator
Rate
Variable
Assignment
& Selection

Command:
Response:

Status:

>add/SMRV_nnnn_mmm.mmm'cr'
RF_OFF'cr''lf']

See MR command.

Where:

nnnn = 1/2, 3/4, 7/8, or BP12 (Coder rate).
mmm.mmm = Data rate in kHz.

Notes:

1. Setting the modulator turns off the RF transmitter.
2. When ADPCM Interface is selected, only 32.000 and

64.000 are allowed.

3. When the Async Interface is used. If the ASYNC

baud rate is higher than allowable for the new data
rate, the maximum baud rate will be selected
automatically.

Set
Modulator
Power
Offset

Command:
Response:

Status:
Response:

>add/MPO_snn.n'cr''lf']

>add/MPO_snn.n'cr''lf']

Where: snn.n = +49.9 to -49.9, in 0.1 dB increments.

Note: The modulator power offset is added to the nominal
power level to adjust the transmit power range.