beautypg.com

External modem connectors, Data i/o interface (j8), 3 external modem connectors – Comtech EF Data SNM-1001 User Manual

Page 25: 1 data i/o interface (j8)

background image

Installation

SNM-1001 Network Control Modem

2–4

Rev. 1

2.3

External Modem Connectors

Connections between the modem and other equipment are made through five connectors.
These connectors are listed in Table 2-1 and their locations are shown in Figure 2-3. The
use of each connector is described in the following paragraphs.

Table 2-1. Rear Panel Connectors

Name

Ref. Design

Function

Connector Type

AC POWER

None

AC Power Input

Standard

DATA I/O

J8

DATA Input/Output (I/O)
EIA-422/449

Various
37-pin D

AGC

None

AGC Test Point

Test Point

FAULTS

J7

FORM-C Fault Relay Contacts

9-pin Female D

REMOTE

J6

Remote Interface

9-pin Female D

TX IF OUTPUT

CP1

TX IF Output

BNC

RX IF INPUT

CP2

RX IF Input

BNC

CHASSIS GND

None

Chassis Ground

#10-32 Stud

Figure 2-3. SNM-1001 Rear Panel View

2.3.1

DATA I/O Interface (J8)

The DATA I/O interface connector is used to interface data input and output signals to
and from the modem. J8 connects to the customer terrestrial equipment directly, or
through a protection switch. The modem operates with a single interface configuration.
The DATA I/O interface is EIA-422/449.