2.3.3 Faults
(J7)
The fault connector on the modem is used to provide FORM-C contact closures for the
purpose of fault reporting. There are three FORM-C summary fault contacts:
•
Modulator
•
Demodulator
•
Common equipment
To obtain a system summary fault, connect all FORM-C contacts in parallel.
The fault interface is provided on a 9-pin female D connector. Screw locks are provided
for mechanical security of the mating connector. The pinout of the connector is as
follows:
Pin #
Name
Function
1
NO
Common equipment is not faulted
2
COM
3
NC
Common equipment is faulted
4
NO
Modulator is not faulted
5
COM
6
NC
Modulator is faulted
7
NO
Demodulator is not faulted
8
COM
9
NC
Demodulator is faulted
Note: A connection between the common (COM) and normally open (NO) contacts
indicates no fault.
2.3.4
TX IF Output (CP1)
CP1 is the transmit IF connector. The output impedance is 75
Ω
. The output power level
is -5 to -30 dBm, in 0.1 dB steps.
In normal operation, the output will be a QPSK modulated result of the DATA I/O