Comtech EF Data RCS10 User Manual
Page 241

Warranty Policy
RCS10 Modem and Redundancy Control System
Page 5-4
TM058 - Rev. 2.3
Signals that are monitored and/or controlled from the front panel or remotely using the RS485 or
Ethernet Remote Port.
Transmit and Receive Frequencies
Transmit and Receive Data Rates
Transmit and Receive Code Rate
Differential Encoding On/Off
Scrambler On/Off, IBS or V.35 Mode, Others
Spectrum Normal/Inverted
Clock Source, Polarity and Frequency
Transmit Carrier On/Off
Transmit Carrier Level
CW, Dual, or Offset
Demodulator Input Level
Eb/No, BER, Corrected BER
Buffer Size, Clock, Center Buffer
Event Buffer
Faults
Sweep Range and Delay
IDR/IBS Backward Alarms, Modem/Switch Alarms
IDR/IBS Framing, Drop and Insert Mode and Flags
Loopback; Terrestrial, Satellite, both or none-interface
Redundancy Switch Auto/Manual, Backup Delay
Environmental
Prime Power:
100 - 240 Vac, 7 A, 50-60 Hz, 450 Watts
Operating Temp.:
0 to 50
°
C, 95% humidity, non-condensing
Storage Temp.:
-20 to 70
°
C, 99% humidity, non-condensing
Physical
Weight (fully-loaded): 100 pounds (45.45 kg.)
Size:
17.25 x 19 x 19 inches
(44.45 x 48.26 x 48.26 cm.)
Shipping Weight: 120 pounds (54.54 kg.)