Swapping the symbol for bpsk – Comtech EF Data RCS10 User Manual
Page 19
Addendum
RCS10 Modem and Redundancy Control System
TM058 - Rev. 2.3
xix
Bit 1 = FMDSP Lock
Bit 2 = T1 signaling fault
Bit 3 = Turbo codec lock fault
Bits 4 – 7 = Spares
Insert after the following line:
RadRCS10_RxAlarm5Status OBJECT-TYPE
DESCRIPTION
Bit 0 = Trellis decoder lock
With:
Bit 1 = FMDSP Lock
Bit 2 = T1 signaling fault
Bit 3 = Turbo codec lock fault
Change
the following line:
RadRCS10_RxAlarm5Status OBJECT-TYPE
DESCRIPTION
Bits 1 – 7 = Spares
To:
Bits 4 – 7 = Spares
Turning On/Off the Fairchild Compatible Scrambler/Descrambler
For the Mod
1.
Go to the ‘Mod Confg’ Screen
2.
Press the ‘Next’ Key 4 times.
3.
‘Type’ will appear. Press ‘More’ until you see ‘V.35 (FC)’.
4.
Press ‘On’ or ‘Off’ as applicable.
For the Demod
1.
Go to the ‘Demod Confg’ Screen
2.
Press the ‘Next’ Key 5 times.
3.
‘Type’ will appear. Press ‘More’ until you see ‘V.35 (FC)’.
4.
Press ‘On’ or ‘Off’ as applicable.
Swapping the Symbol for BPSK
For the Mod
1.
Go to the ‘Mod Confg’ Screen
2.
Press the ‘Next’ Key 7 times.
3.
‘Pairing’ will appear. Press ‘Swapped’ or ‘Normal’ as applicable.
For the Demod