10 bulk configuration string commands, 11 redundancy commands and queries, T. 6.3.10 – Comtech EF Data CDM-840 User Manual
Page 173

CDM-840 Remote Router
Revision 2
Serial-based Remote Product Management
MN-CDM840
7–27
7.3.10
Bulk Configuration String Commands
Parameter
Type
Command
(Instruction
Code
& Qualifier)
Number of
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code &
Qualifier)
Response to Query
(Target to Controller)
Configuration
Load
CLD=
1 byte
Command only.
Retrieves a previously stored modem configuration from Configuration Memory
location defined by the one-byte argument (0 to 9).
Example: <1/CLD=4’cr’
CLD=
CLD?
CLD*
CLD#
N/A
N/A
Configuration
Save
CST=
1 byte
Command only.
Stores the current modem configuration in Configuration Memory location
defined by the one-byte argument (0 to 9).
Example: <1/CST=0’cr’
CST=
CST?
CST*
CST#
N/A
N/A
7.3.11
Redundancy Commands and Queries
Parameter
Type
Command
(Instruction
Code
& Qualifier)
Number of
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code &
Qualifier)
Response to Query
(Target to Controller)
Redundancy
State
N/A
1 byte
Query only.
Returns the redundancy state of the unit in the form x, where:
0=Offline
1=Online
Example: <1/RED?’cr’
N/A
RED?
RED=x
(see description
of Arguments)
Force 1:1
Switch
FSW=
None
Command only.
Forces the unit to toggle the Unit Fail relay to the “fail” state for approximately
500ms.
If the unit is a 1:1 pair and it is currently the ‘Online’ unit, this forces a
switchover so the unit will then be in ‘Standby’ mode.
The command is always executed by the unit regardless of whether it is stand-
alone, in a 1:1 pair, or part of a 1:N system.
Note: This command takes no arguments.
Example: <1/FSW=’cr’
FSW=
FSW*
N/A
N/A