9 unit parameters commands and queries, T. 6.3.9 – Comtech EF Data CDM-840 User Manual
Page 165

CDM-840 Remote Router
Revision 2
Serial-based Remote Product Management
MN-CDM840
7–19
7.3.9
Unit Parameters Commands and Queries
Parameter
Type
Command
(Instruction
Code
& Qualifier)
Number of
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code &
Qualifier)
Response to Query
(Target to Controller)
Equipment ID N/A
37 bytes
Query only.
Returns the equipment ID and installed options, where:
AAAA= The modem model number, i.e, 0840
ssss (4 spares)= Installed hardware = 0000
Software FAST options
B= Tx Data/Symbol Rate option:
0= Standard: CCM 16kbps to 256kbps
1= CCM 16kbps to 512bps
2= CCM 16kbps to 1024kbps
3= CCM 16kbps to 2048kbps
4= CCM 16kbps to 5Mbps
5= CCM 16kbps to 10Mbps
6= CCM 16kbps to 15Mbps
7= ACM 37ksps to 100ksps (future)
8= ACM 37ksps to 200ksps (future)
9= ACM 37ksps to 400ksps (future)
A= ACM 37ksps to 800ksps (future)
B= ACM 37ksps to 1200ksps (future)
C= ACM 37ksps to 2400ksps (future)
D= CCM 37ksps to 4100 ksps (future)
C= Rx Data/Symbol Rate option:
0= Standard: CCM 1Mbps to 15Mbps
1= CCM 1Mbps to 45Mbps
2= CCM 1Mbps to 100Mbps
3= CCM 1Mbps to 140Mbps
4= CCM 1Mbps to 167Mbps
5= ACM 1Msps to 5Msps future
6= ACM 1Msps to 15Msps future
7= ACM 1Msps to 34Msps future
8= ACM 1Msps to 47Msps future
9= ACM 1Msps to 62Msps future
N/A
EID?
EID=AAAAssssBCDEFGHIJ
Ksssssssssssssssssss
(see Description of
Arguments)