3 remote commands and queries, 1 table indexes, 3 remote commands and queries 7.3.1 table indexes – Comtech EF Data CDM-840 User Manual
Page 154

CDM-840 Remote Router
Revision 2
Serial-based Remote Product Management
MN-CDM840
7–8
7.3
Remote Commands and Queries
7.3.1
Table Indexes
Notes:
1. Index Columns – Where Column ‘C’ = Command, and Column ‘Q’ = Query, columns marked ‘X’ designate the instruction code as
Command only, Query only, or Command or Query.
2. In the tables that follow, the following codes are used in the ‘Response to Command’ column (per Sect. D.5.5):
= Message ok
# Message ok, but unit is not in Remote mode.
? Received ok, but invalid arguments were found. ~ Time out of a pass-through message, either to via EDMAC or a local ODU
^ Message ok, but unit is in Ethernet mode.
Sect. 6.3.2 Transmit (Tx) Parameters Commands and Queries
CODE
C
Q PAGE
CODE
C
Q
PAGE
CODE
C
Q
PAGE
TAR
X
X 6-12
TMC
X
X
6-12
TSR
X
X
6-11
TDR
X 6-11
TPL
X
X
6-11
TXO
X
X
6-11
TFQ
X
X 6-11
TSI
X
X
6-12
VFQ
X
6-12
Sect. 6.3.3 Receive (Rx) Parameters Commands and Queries
CODE
C
Q
PAGE
CODE
C
Q
PAGE
RFQ
X
X
6-13
RSI
X
6-14
RGS
X
X
6-14
RSR
X
X
6-13
RMC
X
6-13
Sect. 6.3.4 Demodulator Parameters Commands and Queries
CODE
C
Q
PAGE
CODE
C
Q
PAGE
ESN
X
6-15
RSL
X
6-15