Comtech EF Data CDM-840 User Manual
Page 167

CDM-840 Remote Router
Revision 2
Serial-based Remote Product Management
MN-CDM840
7–21
Parameter
Type
Command
(Instruction
Code
& Qualifier)
Number of
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code &
Qualifier)
Response to Query
(Target to Controller)
Equipment ID
(cont.)
I = Quality of Service
0= None
1= Basic Qos (Diffserv + SAR)
2= Advanced Qos (Basic Qos + Rule Based Qos)
J = G.702 Clock Extension
0= None
1= Enabled
K = Dynamic SCPC
0= None
1= Enabled
sssssssssssssssssss (19 spares)
Example: <1/EID?’cr’
Current
Software
Image
N/A
1 byte
Query Only.
Returns active software image in the form x, where:
1=Bulk Image #1 currently active
2=Bulk Image #2 currently active
Example: <1/IMG?’cr’
N/A
IMG?
IMG=x
(see Description of
Arguments)
Firmware
information
N/A
100 bytes
Query only.
Returns firmware information for Image 0, 1 or 2, where:
0 = Bootrom Information
1 = Image #1 Firmware Information
2 = Image #2 Firmware Information
The information return in the form xxxxx…,mm/dd/yy where:
xxxxx…: The firmware number
mm/dd/yy: The firmware date in month/date/year
Example: <0/FRW?1’cr’
N/A
FRW?0
FRW?1
FRW?2
FRW= xxxxx…,mm/dd/yy
(see Description of
Arguments)
Software
Revision
N/A
8 bytes
Query only.
Returns the value of the internal software revision installed in the unit, in the
form of xx.xx.xx
Example: <0/SWR?’cr’
N/A
SWR?
SWR=xx.xx.xx
(see description
of Arguments)