ToolVox® X3
Administrator Guide
DTMF Dialing Volume – Sets the volume of the DTMF tones during the dialing sequence
Recording Playback level – Sets the volume level of the recordings played back out of the unit and
to the guard.
Answer Ring count – Number of Rings before the unit will answer
Ring-In Unit Speaker – Enable to hear incoming call ring out of the unit speaker
Enable Mass Notification System – Enabling will force the IA4100 to answer incoming calls and
pass the audio to the amp/speaker array.
Mass Notification Outputs - If desired select 1 of the Auxiliary Outputs and a recording to play
from one of the recording memory slots above.
Disable Battery Check - Yes - Do not check the battery. No - Check battery and call number set
above in “Low Battery” Section.
Hang up Methods
Wink Timing – 0=disabled, 1-9 = 100ms to 900ms. Length of the wink signal coming from the
connected phone line.
Revert to dial tone – 00=disabled, 01-99 1 to 99 seconds. Continuous sound for this period of time
will cause the unit to hang up.
Silent Time Out – 0 to 3, 0=disabled, 1=30 sec, 2=60 sec, 3=90 sec. Silence for this period of time
will cause the unit to hang up.
Reorder/Repeating Tones – 00=disabled, 01 to 99= 1 to 99 cycles. This is the number of repeating
cycles that will cause the unit to hang up.
Call Time Out – 00=disabled, 01-99 = 1 to 99 minutes. DTMF tones BBBBB will play to both
parties during a call notifying them 30 seconds prior to call disconnect. At this time the call can be
extended by entering the IN call command 31. Once the timer has expired, if command 31 is not
entered, the unit will hang up.
Wink Voltage Minimum – Minimum voltage change to interpret as a WINK. 0=5V thru 9=14V.
Minimum Ring Voltage Detection – Threshold - 0=13 Vrms, 1=19 Vrms, 2=40 Vrms.
Maximum Ring Frequency – 0=75 Hz, 1=50 Hz, 2=35 Hz.