Outgoing Dial Rules
Dial Rules(Optional): A Dial Rule to set how calls are sent out this trunk. If your outbound call
does not match anything then it will be dialed as is.
• X matches any digit from 0-9
• Z matches any digit from 1-9
• N matches any digit from 2-9
• . is a wildcard that matches one or more characters
• | removes the dialing prefix from the number dialed. Example 9|.
o This would send any number beginning with 9 out this route. 95551212 would
send 5551212 out this trunk.
• + adds a dialing prefix to the number dialed. Example 1616+.
o This would add 1616 to any number sent out this trunk. 5551212 would be
prepended and sent to the carrier as 16165551212.
Dial Rules Wizards(Optional): Useful in creating Dial Rules. You can use the wizard to add or
delete a prefix to numbers or lookup numbers for local calling.
Outbound Dial Prefix(Optional): Enter the outbound dial prefix for Centrex or other custom type of
trunks where you have to dial a 9 etc. to make a call to the PSTN.
Outgoing Settings
Trunk Name: The name you wish the trunk to be identified as.
PEER Details: Enter the details of the IAX2 PEER here. The order of any allow or deny statements
will be followed in order.
USER Context: The user name or account identifier the PEER is expecting.
USER Details: Enter the details of the IAX2 USER here. The order of any allow or deny statements
will be followed in order.
Registration
Register String: The registration string required to authenticate with the IAX2 PEER. Example:
username:[email protected]