GreenStart Igniter 2 for Inserts:

Installation Instructions

(SKU 94400952)

Page 8 of 12

17601768.docx— 10/21/13

© Travis Industries, Inc.

Flush Wood Plus Rectangular Start Button Installation:

Drill a

9

/

64

” pilot hole for the power cord that is 2” from the bottom and 4” from the right edge of the

surround panel. Enlarge the hole with a ½” drill bit.
Insert the color-coded start button through the hole. The start button should be flush with the surround
panel.

Route the igniter cord through the “mouse hole” in the left side of the panel as shown above. Attach the
face to the panel.
Connect the igniter assembly wires; orientation does not matter. Wrap the wires around the compressor
hose.

Connect the igniter assembly wires; orientation does not matter.
Connect the start button wires to the igniter assembly.

NOTE: The wires are color-coded and must be matched.


2”

4”