Avalon Firestyles GreenStart Igniter 2 for Inserts User Manual
Avalon Firestyles Hardware
GreenStart Igniter 2 for Inserts:
Installation Instructions
(SKU 94400952)
Page 1 of 12
17601768— 3/18/14
© Travis Industries, Inc.
Compatibility
Flush Wood Plus Rectangular SN #1401-10265 or greater
Flush Wood Plus Arch SN #1401-10106 or greater
Flush Wood Plus Cape Cod
Large Flush Wood Insert
Small Flush Wood Insert
NOTE: Use the firebrick and igniter housing included with the insert (see the manual for details).
Insert Sizing
The igniter assembly, when installed, protrudes from the left
side of the insert. It requires additional space inside the
fireplace cavity for installation. See the table below for
dimensions required for installation.
Depth
Into
Fireplace
Width at Front
of Fireplace
Small Fl. Wd.
Insert
5” 34.75”
Flush Wood
Plus
3” 36”
Large Fl. Wd.
Insert
3” 40”
NOTE for Flush Wood Plus Rectangular: Use panel trim to
gain extra space if needed.
Electrical Requirements
This kit requires 8 amps, 120 Volt AC.
Installation Tips
Do not place the compressor assembly or excess tubing inside the fireplace.
The igniter must be installed before installing the surround panels.
The compressor assembly must be placed as shown in the instructions. Placing it on its side,
near hot components, or in a location where temperatures go below 40
F will void the warranty
and may lead to premature failure.
You must have a ½” chuck on your drill.
Order of Installation
Remove the shipping screw from the top of the pump box.
Place insert on the hearth with the left side exposed (you may wish to place a protector over the hearth).
Install the igniter assembly.
Attach the start button the panel or trim and plug into igniter assembly.
Place the compressor assembly in a suitable location.
Route the igniter cord to the igniter assembly and attach the quick-connects and air tube.
Plug the compressor assembly into a 120v receptacle and test operation.
Fireplace
Min. Width at Front
of Fireplace
Depth Into
Fireplace