beautypg.com

2 power requirements, Table 3-1, Environmental and thermal requirements – Artesyn PCIE-8120 Installation and Use (July 2014) User Manual

Page 27: Table 3-2, Wattage status, Table 3-3, Power requirements, Hardware preparation and installation

background image

Hardware Preparation and Installation

PCIE-8120 Installation and Use (6806800R89C)

27

The PCIE-8120 temperature sensors provide alerts about absolute and delta temperature level
on the card. For more information on the default values to set up sensor alarms, see

Sensor Alert

Default Values

,

Table B-2 on page 74

.

3.3.2

Power Requirements

Before installing the card, make sure that the system is capable to safely deliver the required
power.Typical wattage status is given for the following operating conditions:

Table 3-1 Environmental and Thermal Requirements

Requirement

Operating

Non-Operating

Temperature

0xC to +55xC

-40xC to +70xC

Forced Air Flow

recommended >0.5m/s

-

Temp. Change

+/-0.25xC/min

+/-0.25xC/min

Rel. Humidity

5% to 90% non-condensing

5% to 95% non-condensing

Vibration
5 to 200Hz

1g sinusoidal

1g sinusoidal

Table 3-2 Wattage Status

Wattage Status

Description

Idle

Card powered and is in the default reset state.

Active

Power good status on all DSP operations.

Maxload

Maximum load test condition (Not achieved during normal operation).

Table 3-3 Power Requirements

PCIE-8120-A12/V12

PCIE-8120-A04/V04

PCIE-8120-A12/V12-N

3.3V current

<100mA

<100mA

<100mA

Typ.Wattage

Idle

20W

12W

20W

Active

35W

15W

32W

Maxload

65W

25W

70W