2 power requirements, Table 3-1, Environmental and thermal requirements – Artesyn PCIE-8120 Installation and Use (July 2014) User Manual
Page 27: Table 3-2, Wattage status, Table 3-3, Power requirements, Hardware preparation and installation

Hardware Preparation and Installation
PCIE-8120 Installation and Use (6806800R89C)
27
The PCIE-8120 temperature sensors provide alerts about absolute and delta temperature level
on the card. For more information on the default values to set up sensor alarms, see
,
.
3.3.2
Power Requirements
Before installing the card, make sure that the system is capable to safely deliver the required
power.Typical wattage status is given for the following operating conditions:
Table 3-1 Environmental and Thermal Requirements
Requirement
Operating
Non-Operating
Temperature
0xC to +55xC
-40xC to +70xC
Forced Air Flow
recommended >0.5m/s
-
Temp. Change
+/-0.25xC/min
+/-0.25xC/min
Rel. Humidity
5% to 90% non-condensing
5% to 95% non-condensing
Vibration
5 to 200Hz
1g sinusoidal
1g sinusoidal
Table 3-2 Wattage Status
Wattage Status
Description
Idle
Card powered and is in the default reset state.
Active
Power good status on all DSP operations.
Maxload
Maximum load test condition (Not achieved during normal operation).
Table 3-3 Power Requirements
PCIE-8120-A12/V12
PCIE-8120-A04/V04
PCIE-8120-A12/V12-N
3.3V current
<100mA
<100mA
<100mA
Typ.Wattage
Idle
20W
12W
20W
Active
35W
15W
32W
Maxload
65W
25W
70W