Features, Functions, and Specifications

Sorensen SF Series

1-2 M550292-03

(Programming)

Readback Functions

• Actual measured voltage and current

• Current

settings

• Soft current limit

• Status and Accumulated Status registers

• Programming error codes

• Fault

codes

• Manufacturer, power supply model, and firmware version identification

1.3 Specifications

Programming Resolution

Current:

0.002% of full scale

Programming Accuracy

Current:

± ( 0.4% of maximum output current)*

Readback Resolution

Voltage:

± 0.002% of full scale

Current:

± 0.002% of full scale

Readback Accuracy

Voltage:

± ( 0.15% of full scale output voltage)

Current:

± ( 0.4% of full scale output current)*

* After 30 minutes operation with fixed line, load, and temperature.

Note: Refer to the SFA or SFI power supply Operation manual for effects of line regulation,

load regulation, and temperature on accuracy specifications.

Specifications subject to change without notice.