IEEE 488.2 and SCPI Command Operation
3.6.2
MEASURE SCPI Command Reference
In the following table a "C" in the SCPI column indicates that the command is SCPI-compliant.
Command Description
SCPI
MEASure
Measure subsystem.
C
:CURRent?
Returns the floating point value of the DC output
current in amps.
C
:CURRent
:AVErage
Enter a value of 1 to 5 to set the number of readings
to average together when returning the current value
from the MEAS:CURR? command. This function
reduces noise in the readback readings. The
(default) value of 1 provides the fastest response
time, but the noisiest readings.
N
:AVErage?
Returns the number 1 to 5 to indicate the last set
number of readings to average together when taking
a current reading.
N
:VOLTage?
Returns the floating point value of the DC output
voltage in volts.
C
:VOLTage
:AVErage
Enter a value of 1 to 5 to set the number of readings
to average together when returning the voltage value
from the MEAS:VOLT? command. This function
reduces noise in the readback readings. The
(default) value of 1 provides the fastest response
time, but the noisiest readings.
N
:AVErage?
Returns the number 1 to 5 to indicate the last set
number of readings to average together when taking
a voltage reading.
N