3.11.2 CALIBRATION SCPI Command Reference

In the following table a "C" in the SCPI column indicates that the command is SCPI-compliant.
The Q? column indicates whether the command can also be used for querying.

Command Description

SCPI

Q?

CALibrate

Calibration subsystem.

C

:DATA





Sets the values of the ten floating point
calibration constants:
1) not used
2) not used
3) output current DAC gain
4) output current DAC offset
5) output current protection DAC gain
6) output current protection DAC offset
7) voltage measurement ADC gain
8) voltage measurement ADC offset
9) current measurement ADC gain
10) current measurement ADC offset
Values are separated by space or comma.

N

:INITial

N

:CURRent

Sets the power-on default value of current.

N

Q

:PROTection Sets the power-on default value of the

overcurrent protection.

N Q

:LOCK

Disables access to the non-volatile memory.
Prevents attempts to store calibration
values.

N

:MEASure

N

:CURRent

:ADC?

Returns the integer value of the A/D for the
current measurement.

N

:CALCulate

Calculates the value of the gain and offset
for current measurements.

N

:GAIN

Sets the value of the gain for current
measurements.

N Q

:OFFSet

Sets the value of the offset for current
measurements.

N Q

:POINt <1|2>
<0+NRf>

Sets the current measurement calibration
point (1 or 2). The actual output current is
measured with an external meter.

N

:VOLTage

N

:ADC?

Returns the integer value of the A/D for the
voltage measurement.

N

:CALCulate

Calculates the value of the gain and offset
for voltage measurements.

N

:GAIN

Sets the value of the gain for voltage
measurements.

N Q

:OFFSet

Sets the value of the offset for voltage
measurements.

N Q

M550292-03 (Programming)