-200

Execution error
An error/event number in the range [-299,-200] indicates that an error has
been detected by the instruments execution control block. The occurrence
of any error in this class shall cause the execution error bit (bit 4) in the
Event Status Register to be set. An execution error can be the result of:
• A element out of range, such as programming 35 volts
in a 33 volt device.
• A command could not be executed due to the current condition of the
device.

-203

Command protected
Attempted to store calibration values to EEPROM without unlocking.

-221

Settings conflict
Attempted to set output greater than soft limits or to set soft limits less than
output.

-222

Data out of range
Parameter exceeded range of valid values.

-225

Out of memory
There is not enough memory to perform the requested operation.

-241

Hardware missing
A legal command or query could not be executed because of a hardware
fault.

-284

Program currently running
A legal command or query could not be executed because a function is
currently running.

-292

Referenced name does not exist

-293

Referenced name already exists

-316

Checksum error

-330

Self-test failed
A self-test failure has occurred.

-340

Calibration failed
Error during calculation of calibration values occurred.

-350

Queue overflow
The error queue can contain up to 10 entries. If more than 10 error/event
conditions are logged before the SYSTem:ERRor? query, an overflow will
occur; the last queue entry will be overwritten with error -350. When the
queue overflows, the least recent error/events remain in the queue and the
most recent error/events are discarded.

-360

Communication error
Communications to a channel was disrupted.