AMETEK SFA Series Programming Manual User Manual
Page 17

Sorensen SF Series
IEEE 488.2 and SCPI Command Operation
Error Code Description
-200
Execution error
An error/event number in the range [-299,-200] indicates that an error has
been detected by the instruments execution control block. The occurrence
of any error in this class shall cause the execution error bit (bit 4) in the
Event Status Register to be set. An execution error can be the result of:
• A
in a 33 volt device.
• A command could not be executed due to the current condition of the
device.
-203
Command protected
Attempted to store calibration values to EEPROM without unlocking.
-221
Settings conflict
Attempted to set output greater than soft limits or to set soft limits less than
output.
-222
Data out of range
Parameter exceeded range of valid values.
-225
Out of memory
There is not enough memory to perform the requested operation.
-241
Hardware missing
A legal command or query could not be executed because of a hardware
fault.
-284
Program currently running
A legal command or query could not be executed because a function is
currently running.
-292
Referenced name does not exist
-293
Referenced name already exists
-316
Checksum error
-330
Self-test failed
A self-test failure has occurred.
-340
Calibration failed
Error during calculation of calibration values occurred.
-350
Queue overflow
The error queue can contain up to 10 entries. If more than 10 error/event
conditions are logged before the SYSTem:ERRor? query, an overflow will
occur; the last queue entry will be overwritten with error -350. When the
queue overflows, the least recent error/events remain in the queue and the
most recent error/events are discarded.
-360
Communication error
Communications to a channel was disrupted.
M550292-03 (Programming)
3-5