Source scpi command reference -10 – AMETEK SFA Series Programming Manual User Manual
Page 22

IEEE 488.2 and SCPI Command Operation
Sorensen SF Series
3.5.2
SOURCE SCPI Command Reference
In the following table a "C" in the SCPI column indicates that the command is SCPI-compliant.
The Q? column indicates whether the command can also be used for querying.
Command Description
SCPI
Q?
SOURce
Source subsystem.
C
:CURRent
Sets the output current in amps (default) or in
milliamps.
C Q
[:LEVel]
Sets the output current in amps (default) or in
milliamps.
C Q
[:IMMediate]
Sets the output current in amps (default) or in
milliamps.
C Q
[:AMPLitude]
<0+NRf>
Sets the output current in amps (default) or in
milliamps.
C Q
:TRIGgered
Sets the value of the output current to be
implemented by the trigger.
C Q
:CLEar
Clears the trigger mode.
[:AMPLitude]
<0+NRf>
Sets the value of the output current to be
implemented by the trigger.
C Q
:LIMit
Sets an upper soft limit on the programmed
output current for the supply. The soft limit
prevents the supply from being inadvertently
programmed above the soft limit, thus
providing a method for protecting the load
against damaging currents.
C Q
[:AMPLitude]
<0+NRf>
Sets an upper soft limit on the programmed
output current for the supply.
C Q
:RAMP <0+NRf>
<0+NRf>
Sets the output current to ramp from the
present value to the specified value (first
argument) in the specified time (second
argument). See Ramp Function description
below.
N Q
:ABORt
Aborts ramping and clears trigger mode.
:ALL?
Returns the ramping status of all channels.
:TRIGgered
<0+NRf>
<0+NRf>
Sets the output current to ramp from the
present value to the specified value (first
argument) in the specified time (second
argument) upon the trigger command. See
Ramp description below.
N Q
:ONLine?
Returns the integer value 1(ONLINE) or 0
(OFFLINE) of the channel online status.
N
3-10 M550292-03
(Programming)