IEEE 488.2 and SCPI Command Operation

Sorensen SF Series

THE RAMP FUNCTION

The ramp function allows the user to transition from one current to another linearly in a specified
time period (100 ms - 99 sec with 100 ms programming resolution). A unit may ramp only
current.

Current ramping requires an appropriate resistive load.

SOURce[n]:STATus:BLOCK? "Status Flags" REGISTER

Bit Hex

Value Name

Description

0

0x001

remote mode

Remote mode was selected.

1

0x002

Not used.

2

0x004

PON SRQ

PON Service Request selected by rear panel switch.

3 0x008

SRQ

sent

GPIB Service Request issued and the serial poll has
not been received.

4

0x010

EEPROM

The EEPROM is locked.

5

0x020

trip occurred

Either an OV or OT trip occurred.

6

0x040

sense signal

Not used.

7

0x080

isolation signal Not used.

8

0x100

hold

Current output waiting for trigger.

9

0x200

fold

Foldback protection is enabled.

10

0x400

SRQ enabled

Service Request generation is enabled.

11

0x800

output

Output is on.


3.6

3.6.1

MEASURE SCPI Command Subsystem

MEASURE SCPI Command Summary

MEASure
:CURRent?
:CURRent
:AVErage

:AVErage?
:VOLTage?
:VOLTage
:AVErage

:AVErage?

3-12 M550292-03